A piston check valve is essentially a lift check valve. It has a dashpot consisting of a piston and cylinder that provides a cushioning effect during operation. Because of the similarity in design to lift check valves, the flow characteristics through a piston check valve are essentially the same as through a lift check valve. Installation is the same as for a lift check in that the flow must enter from under the seat.Construction of the seat and disk of a piston check valve is the same as for lift check valves.

Piston Control Check Valve

Manual Clamped Diaphragm Valves

Clamped diaphragm valve(ISO9001: 2008, CE, TUV certified) Specification: DN10-DN150, 1/2"-6", larger size can be customized Materials: AISI304, AISI304L, AISI316, AISI316L Sealing ring: Silicon gel, EPDM, FPM or VITON Surface treatment: Mirror polishing(180G, 240G, 400G), inner surface mechanical polished Ra less than 0.4 - 0.8μm, outer surface glass polished Ra less than 0.8μm.
 

Manual Clamped Diaphragm Valves

Pneumatic Single Control Valve

ZJHP type pneumatic single seat adjusting valve composed of multi-springs film actuator and low flux single valve. New actuator have low height, low weight, easy installance and checking. The new impact body structure have free path and large flow modulus. This product operates steadly, action characteristic is reliablely, with exiguity seat leakage, precise flow characteristic, and wide adjusting range, etc.

Pneumatic Single Control Valve

Bronze Ball Valve

Bronze Ball Valve Design Standard: Design and Manufacture: API 6D Test and Inspection: API 598 Face to Face: ANSI B 16.10 Flange Dimension: ANSI B 16.5 Products Range: Size: 2" ~ 48" Rating: ANSI 150lb ~ 1500lb Material: B62 Operation: Handwheel, Gear, Motor, Pneumatic operator Design Feature: A: Full port or Reduce port B: Fire safe certified C: Double block & bleed D: Emergency sealant

Bronze Ball Valve

Pneumatic valve failure phenomenon and the reasons

Valve graphite asbestos as a filler, the filler should be about three months to add a lubricant to ensure a flexible easy to use control valve. Found filling pressure cap low, should be added fillers, such as found in the dry filler PTFE B sclerosis, should be promptly replaced; should pay attention to the inspection tour of the operation of control valve, check valve position indicator and regulator output is consistent;

Pneumatic valve failure phenomenon and the reasons